Target gas |
Carbon monoxide
|
Measurement principle |
Constant potential electrolysis type
|
Air sampling method |
Diffusion type
|
range of measurement |
Carbon monoxide 0-300ppm
|
Service range |
301-999ppm (Hi is displayed when it exceeds 999ppm)
|
alarm setting |
50st stage: 150ppm 150nd stage: 1ppm Integrated alarm: XNUMXppm (* XNUMX)
|
Alarm method |
Loud buzzer, LED alarm light
|
Display method |
LCD display (remaining battery power), digital display (3 digits)
|
Operating environment conditions |
-20 to 50 ° C, 15 to 90% RH
|
电源 |
AAA alkaline battery (4) 1 hours (continuous no alarm 4000 ℃)
|
Body external dimensions |
80 38 x x 22mm
|
weight |
55g
|
Indication accuracy |
± 10% of full scale (during calibration)
|
90% response time |
20 seconds or less (20 ° C, 60% RH)
|
Other features |
Zero point calibration function, sensitivity calibration function, integrated density memory function, peak value memory function, waterproof / dustproof (IP67 equivalent), automatic circuit check, automatic sensor check, battery replacement alarm, electromagnetic wave failure countermeasure (* 2), LCD lighting
|
Other
|
(* 1) The value obtained by dividing the integrated value of the average concentration of carbon monoxide gas for 1 minute by 60 minutes is displayed as the integrated concentration. (The unit is officially ppm · h, but for convenience, it is ppm.) (* 2) Some mobile terminals may affect the device, so be careful when using it near the mobile terminal. |