LANGUAGE

  1. TOP
  2. Find a gas sensor
  3. Applied products

Applied product Portable CO detection alarm (NDP-CO1A) Portable CO detection alarm (NDP-CO1A)

  • Sensor application products
  • Industrial alarm
  • Applied products
  • Applied products

NDP-CO1A is a portable CO alarm equipped with an electrochemical sensor. It is equipped with a two-step alarm of 50 and 150 ppm and an integrated concentration alarm of 2 ppm · hr, and an alarm sounds and the LED blinks.It is mainly used indoors where steelworks and combustion equipment are installed.

Measurement range
Carbon monoxide / CO 0-300ppm
Detection target gas
Carbon monoxide / CO

Hydrogen gas alarm (NDR-H2-1A) Hydrogen alarm (NDR-H2-1A)

  • Sensor application products
  • Alarm
  • Applied products
  • hydrogen
  • Applied products
  • explosion prevention
Hydrogen alarm, gas chromatography, leak detection, hydrogen gas, hydrogen alarm

Product Description The hydrogen alarm (NDR-H2-1A) is a device that detects leaked hydrogen gas with high accuracy and alerts the surrounding area to danger. With a threshold of 500 ppm, it immediately issues an alarm with a buzzer and LED lamp when gas is detected. The power supply is AC100V, and an A-contact relay is provided for the external output. The contact is normally conductive and disconnected when an alarm occurs. It can be used in a variety of ways, from simple installation to device linkage. *Gas alarms are devices that require regular inspection and calibration to maintain accurate detection performance. Please consult us in advance if you are considering installing it in a high place or a place that is difficult to access. We can also propose an installation method that takes into account the maintenance plan. Examples of use ●Around gas chromatography equipment ●Near hydrogen cutting equipment ●Hydrogen cylinder installation location Features ●Uses a proven in-house contact combustion gas sensor: Achieves high reliability and accuracy. ●LED displays hydrogen gas concentration in three stages: Power, trouble, and alarm status can be confirmed at a glance. ●General household AC3V outlet specification: Easy to install and operate. ●Loud buzzer (approx. 100 dB): Ensures attention in an emergency. ●Wall-mounted installation: Can be installed in limited spaces.

Measurement range
500 to 20,000ppm (range error 15%)
Detection target gas
hydrogen
Hydrogen alarm, gas chromatography, leak detection, hydrogen gas, hydrogen alarm

NGB-3A Gas sensor unit transmitter (4-20mA output)

  • Electrochemical formula
  • Carbon monoxide
  • Hydrogen sulfide
  • ammonia
  • Applied products
  • Concentration measurement

Product Overview The Gas Sensor Unit Transmitter (NGB-3A series) is a 4-20mA current output module developed for our electrochemical gas sensors (CO, H₂S, NH₃). It can be easily incorporated into equipment because it provides an output proportional to the gas concentration. By using this module, connection is easy and the development man-hours for gas detection systems can be significantly reduced. Recommended for the following needs: Want to incorporate a gas sensor into equipment Want to collect data with 4-20mA standard output Looking for a small, lightweight module When voltage output (1-5V) is required (optional) Product features ✅ 4-20mA output proportional to gas concentration ✅ Compact design (40mm x 28mm, approx. 6g) ✅ Optimized for our electrochemical sensors (CO/H₂S/NH₃) ✅ Equipped with zero and span adjustment functions ✅ Compatible with DC12V to 24V power supply ✅ Maximum load resistance of 700Ω ✅ Optional 1-5V voltage output also available ✅ Straight/right angle/connector type pin selectable Usage examples ⚡ Incorporation into environmental monitoring equipment ⚡ Safety monitoring in factories and research facilities ⚡ Portable gas detector development Specifications list Item Specifications Compatible sensors Our electrochemical sensors (CO, H₂S, NH₃) Output 4-20mA (option: 1-5V voltage output) Power supply voltage: DC12V to 24V Maximum load resistance: 700Ω (at DC24V) Board size: Approx. 40mm x 28mm Board weight: Approx. 6g Operating temperature range: 0 to 40°C Product variations Model Pin specifications Features NGB-3APS Straight pin header Standard configuration NGB-3APR Right angle pin header For devices with height restrictions NGB-3ACS Straight connector Cable Easy to connect configuration Notes ● Adjust the output zero and span carefully. ● Use the power supply voltage and load resistance within the specified range. ● We recommend storing the sensor for a maximum of 6 months. ● Avoid condensation and water immersion during storage and installation. Please feel free to contact us with any questions or introduction consultations regarding this product. We can make more accurate suggestions if you tell us the installation environment and use purpose.

Measurement range
Detection target gas

High precision alcohol detection unit (NDP-C2H5OH-4A) High precision alcohol detection unit

  • For consumer
  • Industrial
  • Sensor application products
  • Alarm
  • Consumer alarm
  • Industrial alarm
  • alcohol
  • Applied products
  • Industrial
  • industrial alarm
  • Breath check
  • Applied products
  • Concentration measurement
  • ethanol

This is an alcohol detection unit equipped with our electrochemical breath alcohol sensor. Using a high-precision pump system that is not available from other companies, we are able to perform evaluations and measurements that maximize the performance of the sensor.

Measurement range
Detection target gas

Compact hydrogen gas alarm (NDR-H2-2C) Small hydrogen alarm (NDR-H2-2C)

  • Sensor application products
  • Applied products
  • hydrogen
  • Applied products
  • explosion prevention

Compact hydrogen alarm (NDR-H2-2C) Product description The compact hydrogen alarm detects leaked hydrogen gas and alerts the surrounding area of ​​the risk of gas leakage. While it has the same performance as the standard model (NDR-H2-1A), its compact design allows it to be used in environments with limited installation space. It issues an alarm with a buzzer and LED lamp at a threshold of 500 ppm. The power supply is AC100-240V, and the external output is equipped with a c-contact relay. It can be used in a variety of ways, such as equipment linkage and simple installation. *C-contact type specification. Examples of use ●Around gas chromatography equipment ●Near hydrogen cutting equipment ●Near hydrogen cylinders (places with limited installation space) Features ●Uses our own proven contact combustion gas sensor: Boasts high reliability and accuracy. ●LED displays hydrogen concentration level in three stages: You can check the power supply, trouble, and gas alarm status at a glance. ●Compact body: The compact design allows you to install it in any space. ●Can be used with a general household AC100V outlet: Easy to install and use. ●Loud alarm sound (93dB): Ensures attention in an emergency. ●Can be wall-mounted: Allows for effective use of space. Please feel free to request a quote. If you have any questions regarding the installation environment or maintenance, please feel free to contact us.

Measurement range
500 to 20,000 ppm
Detection target gas
hydrogen

Hydrogen alarm (NDR-H2-1B) Hydrogen gas alarm (NDR-H2-1B)

  • Sensor application products
  • Applied products
  • hydrogen
  • Applied products
  • explosion prevention

Product DescriptionThe hydrogen alarm (NDR-H2-1B) is a device that detects leaked hydrogen gas with high accuracy and alerts the surrounding area with an alarm. The detection concentration threshold is 500 ppm, and when gas is detected, an alarm is immediately sounded by a buzzer (approximately 93 dB) and an LED lamp. The power supply is AC100V. The external output uses a B contact relay (AC250V 1A, resistive load), which is normally open, but when an alarm occurs, the contact closes, allowing for reliable signal transmission to external devices. In this model, the circuit is normally open and closes when an alarm occurs, so it can be easily linked to external buzzers, patrol lights, equipment stop devices, etc. This makes it easy to build a system that reliably and immediately notifies the alarm in the event of an abnormality or safely stops the equipment. *When connecting to an external device, be careful not to exceed the relay contact rating (AC250V 1A, resistive load). It is recommended to use a relay when connecting a high-current device. *Gas alarms are devices that require regular inspection and calibration to maintain accurate detection performance. Please consult us in advance, especially if you are considering installing it in a high place or a place where access is difficult. We can also propose an installation method that takes into account the maintenance plan. *A contact specification model (NDR-H2-1A) is also available separately. Examples of usage ●Around gas chromatography equipment ●Near hydrogen cutting equipment ●Hydrogen cylinder installation location ●When you want to link with a buzzer, patrol light, or stop device Features ●Equipped with a proven in-house contact combustion gas sensor: High reliability and stable detection performance. ●LED 3-stage display: Power, trouble, and alarm status can be confirmed at a glance. ●AC100V power supply specification: Easy installation and operation. ●Loud buzzer (approx. 93dB): Ideal for calling attention in an emergency. ●Wall-mounted installation: Effective use of space. ●Equipped with B contact relay: Signal transmission to external devices is possible when an alarm occurs. Please be careful of the load capacity. We are always available to provide estimates and consultations regarding introduction considerations. Also, please feel free to contact us if you have any questions regarding the installation environment or operation.

Measurement range
500 to 20,000 ppm
Detection target gas
hydrogen
ja JP
ja JPen EN