LANGUAGE

  1. TOP
  2. Find a gas sensor
  3. Hydrogen sulfide

hydrogen sulfide gas sensor NE4-H2S-100

  • Industrial
  • Industrial alarm
  • Disaster countermeasure measuring instrument
  • Electrochemical formula
  • Hydrogen sulfide

NE4-H2S-100 is an electrochemical hydrogen sulfide gas sensor.Since the output current is quite large, the lower limit of measurement is low, and it has excellent selectivity, responsiveness, and durability, and can be applied to a wide range of applications.In addition to this standard product, sensors suitable for the high concentration range (200ppm, 500ppm) are also available.

Measurement range
Hydrogen sulfide / H2S 0-100ppm, 0-200ppm, 0-500ppm
Detection target gas
Hydrogen sulfide / H2S

hydrogen sulfide gas sensor NE7-H2S

  • Industrial
  • Industrial alarm
  • Disaster countermeasure measuring instrument
  • Electrochemical formula
  • Hydrogen sulfide

NE7-H2S is an industrial electrochemical hydrogen sulfide gas sensor. It is mainly used as a stationary gas alarm or measuring device. This sensor operates in a wider concentration range than the regular NE4-H2S, and is a gas sensor with excellent response characteristics and durability against high concentrations. "

Measurement range
Hydrogen sulfide / H2S 0-200ppm
Detection target gas
Hydrogen sulfide / H2S

Electrochemical gas sensor NE7-H2S-S

  • Industrial
  • Industrial alarm
  • Air pollutants
  • Electrochemical formula
  • Hydrogen sulfide

NE7-H2S-S is an industrial electrochemical gas sensor.It is mainly used as a stationary gas alarm and measuring instrument.Since this sensor has high gas sensitivity and high resolution, it is possible to detect trace amounts of hydrogen sulfide in the atmosphere with high accuracy.

Measurement range
Hydrogen sulfide / H2S 0-10ppm
Detection target gas
Hydrogen sulfide / H2S

Electrochemical gas sensor NAP-520

  • For consumer
  • Consumer alarm
  • Disaster countermeasure measuring instrument
  • Special purpose measurement Combustion exhaust measuring instrument
  • Electrochemical formula
  • Hydrogen sulfide

NAP-520 is an electrochemical gas sensor for detecting hydrogen sulfide and can be used for various gas detectors.It has high performance, high stability and small size, and is suitable for portable devices that can be carried by workers.

Measurement range
Hydrogen sulfide / H2S 0-100ppm
Detection target gas
Hydrogen sulfide / H2S

hydrogen sulfide gas sensor NAP-523

  • For consumer
  • Consumer alarm
  • Disaster countermeasure measuring instrument
  • Special purpose measurement Combustion exhaust measuring instrument
  • Electrochemical formula
  • Hydrogen sulfide

NAP-523 is a 3-electrode type electrochemical gas sensor developed to detect hydrogen sulfide.This sensor is highly sensitive and has extremely high selectivity for hydrogen sulfide.Due to the small size of this sensor, it is a gas sensor that can be mounted on portable devices such as bad breath checkers.

Measurement range
Hydrogen sulfide / H2S 0-0.5ppm
Detection target gas
Hydrogen sulfide / H2S

NGB-3A Gas sensor unit transmitter (4-20mA output)

  • Electrochemical formula
  • Carbon monoxide
  • Hydrogen sulfide
  • ammonia
  • Applied products
  • Concentration measurement

Product Overview The Gas Sensor Unit Transmitter (NGB-3A series) is a 4-20mA current output module developed for our electrochemical gas sensors (CO, H₂S, NH₃). It can be easily incorporated into equipment because it provides an output proportional to the gas concentration. By using this module, connection is easy and the development man-hours for gas detection systems can be significantly reduced. Recommended for the following needs: Want to incorporate a gas sensor into equipment Want to collect data with 4-20mA standard output Looking for a small, lightweight module When voltage output (1-5V) is required (optional) Product features ✅ 4-20mA output proportional to gas concentration ✅ Compact design (40mm x 28mm, approx. 6g) ✅ Optimized for our electrochemical sensors (CO/H₂S/NH₃) ✅ Equipped with zero and span adjustment functions ✅ Compatible with DC12V to 24V power supply ✅ Maximum load resistance of 700Ω ✅ Optional 1-5V voltage output also available ✅ Straight/right angle/connector type pin selectable Usage examples ⚡ Incorporation into environmental monitoring equipment ⚡ Safety monitoring in factories and research facilities ⚡ Portable gas detector development Specifications list Item Specifications Compatible sensors Our electrochemical sensors (CO, H₂S, NH₃) Output 4-20mA (option: 1-5V voltage output) Power supply voltage: DC12V to 24V Maximum load resistance: 700Ω (at DC24V) Board size: Approx. 40mm x 28mm Board weight: Approx. 6g Operating temperature range: 0 to 40°C Product variations Model Pin specifications Features NGB-3APS Straight pin header Standard configuration NGB-3APR Right angle pin header For devices with height restrictions NGB-3ACS Straight connector Cable Easy to connect configuration Notes ● Adjust the output zero and span carefully. ● Use the power supply voltage and load resistance within the specified range. ● We recommend storing the sensor for a maximum of 6 months. ● Avoid condensation and water immersion during storage and installation. Please feel free to contact us with any questions or introduction consultations regarding this product. We can make more accurate suggestions if you tell us the installation environment and use purpose.

Measurement range
Detection target gas

NDS-9A-H2S Fixed hydrogen sulfide alarm (NDS-9A-H2S)

  • Sensor application products
  • Electrochemical formula
  • Applied products
  • Hydrogen sulfide
  • Applied products
  • Applied products
  • addiction prevention

Product Description: The NDS-9A-H2S fixed hydrogen sulfide alarm monitors the H₂S (hydrogen sulfide) concentration in a space in real time and reliably sounds an alarm via a buzzer and LED display when a dangerous concentration is reached. Alarm history and concentration data are automatically saved in a log and can be easily retrieved using a USB memory stick. Its design helps streamline facility management and record-keeping. In addition, relay contact output allows linking with external devices such as exhaust equipment and interlocks in the event of an alarm, making it easy to incorporate into safety systems for factories and facilities. *Regular inspection and calibration are required to maintain sensor performance. Please consult us in advance if you are planning to install the alarm at high altitudes or in locations where maintenance is difficult. 🔷 Applications Monitoring hydrogen sulfide at sewage treatment plants and wastewater treatment facilities Monitoring H₂S concentrations at chemical plants Safety management at hot spring facilities and in areas where volcanic gas is emitted Managing the risk of hydrogen sulfide leaks at factory facilities Main Features 8 LED displays + 2-stage buzzer provide step-by-step notifications from caution to alarm Real-time H₂S concentration display using 7-segment LED Automatic log storage of alarm history and concentration data Data can be saved to USB memory in CSV format Alarm-linked relay contact output for easy connection to external devices AC100V specification allows for easy power supply from a household outlet Wall-mountable, compact design (130 x 90 x 45 mm / 360g) High reliability and long life thanks to in-house developed sensors

Measurement range
0-100ppm
Detection target gas
Hydrogen sulfide
ja JP
ja JPen EN