NCP-50SNCP-50S gas sensor is a single header type for industrial application, and it has been already available also in many customers for handheld, wearable or portable applications. Since this type has a simplified explosion proof structure, however it is recommended that it is installed in the approved body by ATEX, CSA or etc. Dimensions
|
NCP-50S's Structure |
Target gases and Concentration
Relative sensitivity
Gases | LEL | Relative | |
1 | Methane | 5.00% | 100 |
2 | Propane | 2.20 | 90 |
3 | n-Butane | 1.80 | 90 |
4 | n-Pentane | 1.40 | 85 |
5 | n-Hexane | 1.20 | 80 |
6 | n-Heptane | 1.05 | 75 |
7 | n-Octane | 0.95 | 70 |
8 | Methanol | 6.70 | 160 |
9 | Ethanol | 3.30 | 120 |
10 | IPA | 2.20 | 110 |
11 | Acetylene | 2.50 | - |
12 | CO | 12.50 | 160 |
13 | Acetone | 2.60 | 110 |
14 | MEK | 1.90 | 90 |
15 | Toluene | 1.20 | 90 |
16 | Ethyl acetate | 2.20 | 90 |
17 | Hydrogen | 4.00 | 150 |
18 | Ammonia | 15.00 | 130 |
19 | Gasoline Pb free | 1.20 | 70 |
20 | Ethylene | 2.70 | 130 |
* : 「-」 means that it is not a detected gas.
** : R.S. (relative sensitivity) is described in case that sensitivity to methane is 100.
Gas sensitivity characteristics
Gas & Concentration | Output voltage |
---|---|
Standard sensitivity 10%LEL of methane | 60 - 110mV |
Zero offset in air | -20 - +20mV |
Ratings
Items | Ratings |
---|---|
Supply voltage | 4.25 V |
Current (4.25V supplied) | 45 - 55mA |
Ambient Temperature | In operation -20 - +60°C |
Ambient humidity | In operation 95%RH or less (No dew condensation) |
Measurement range | Less than 100%LEL |