Sensor (RC) |
NAP-80S
|
Detection gas |
Incomplete combustion exhaust gas
|
Applied voltage |
2.0 ± 0.1V
|
Clean air output |
30 +/- 3mV
|
Detection concentration range |
Within 1% (including 0.5% hydrogen)
|
Output value * Methane, isobutane, propane, hydrogen sensitivity (10% LEL) |
1000ppmCO + 500ppmH2: 5 -7mV
|
Current consumption (at applied voltage) |
150+/-10mA
|
Operating environment (temperature conditions, humidity conditions) |
-20 ~ + 200 ℃ Less than 95% RH without condensation
|
Storage environment |
-30 ~ + 70 ℃ Less than 99% RH without condensation
|
Response time (T90) |
T90: Within 10 seconds
|
Same day reproducibility |
Zero point: ± 0.5 mV Gas sensitivity: ± 0.5% LEL
|
Annual zero point drift |
Zero point: +/- 2mV / year
|
Long-term stability |
Sensitivity: +/- within 2 mV / month
|
Design life |
5 years or more (in appropriate consumer and small commercial applications)
|
Recommended storage period |
6 months
|
Straightness |
50% LEL |